You can switch back to visual editing at any time by clicking on this icon.
xxxxxxxxxx
== '''Safety''' ==
=== '''PPE''' ===
Required PPE for the Vibratory Tumbler include:
* SAFETY GLASSES
* PROTECTIVE FOOTWEAR
* HEARING PROTECTION
{{Discuss |
* According to the manual "Noise levels produced by various Mr Deburr vibratory systems, as measured at the C&M Topline factor, range from 81 to 93 decibels. Do we assume that our machine is at the high end of that range? Considering the small space it is in I would suggest so. If so, the [[hearing protection]] that should be used [https://www.safemanitoba.com/Page%20Related%20Documents/resources/GD_HearingConservationAndNoiseControl_20SWMB.pdf should be an NRR of at least 24]. Does the fablab provide this at the tool or should the user provide their own? [[User:Ttenbergen|Ttenbergen]] ([[User talk:Ttenbergen|talk]]) 00:15, 2024 September 27 (CDT)
* All other members performing other work in the room would have to wear the same [[hearing protection]] while this machine runs.
}}
* Nitrile Gloves when mixing solutions
* Does the fablab provide these? Also, are protective gloves needed when removing the parts from the tumbler, and are nitrile gloves tough enough for that task? }}
* Splash goggles when mixing or dispensing lubricants
* Does the fablab provide these? }}
=== '''Hazards''' ===
* Splashing lubricant
* Handling sharp metal parts
* Vibrating machine
* Wet floor
* Pinching injuries when removing parts from operating machine
* Equipment damage due to overloading machine (max capacity 100 lbs)
* Eye and skin irritation when using cleaners, rust inhibitors, and other solutions
** L-100 is corrosive, others will irritate skin and eyes
{{Discuss | what is L-100; we need a sds link on the main page for the tool }}
** If splashed on skin, remove contaminated clothing and rinse affected area
** If splashed in eyes, use eye wash to flush the affected eye
* manual mentions risk of fire or explosion when using unapproved lubricants, this needs to be reflected here